Skip to content
Global Caché
  • ProductsExpand
    • Global Connect
    • Create Custom Global Connects
    • Flex
    • iTach
    • GC-100 Network Connector
    • Solutions
  • PartnersExpand
    • All Distributors
    • US Distributors
    • International Distributors
    • Dealer Direct Program
  • News & EventsExpand
    • News
    • Events
  • SupportExpand
    • Portal
    • Get Support
    • Docs & Downloads
    • Training (YouTube)
  • CompanyExpand
    • The Team
    • Marketing Resources
    • Contact Us
IR DATABASE
BUY
Global Caché

Home/GC-100/GC-100 sensors

GC-100

GC-100 sensors

Explore sensing options for GC-100 and Global Connect IR modules.

Sensors for GC-100 and Global Connect

Standard 2-year warranty

A separate power source is not required when used with our devices.

Also Available: Infrared Accessories

  • AC/DC
  • Contact Closure
  • GC-SP1 voltage sensor

GC-SP1 AC/DC Voltage Sensor 

The GC-SP1 detects AC or DC voltage and reports whether voltage is present. Use it with a GC-100 network adapter or a Global Connect IR module with its port configured for sensor input.

MPN: GC-SP1

DC Voltages ≥ ±1.5V
AC Voltages ≥ ± 1.5V
P-P for Frequencies ≥ 10Hz


Cable Length: 6 feet (1.8 meters)
Standard 2-year warranty

Ideal for detecting high voltage (via AC wall adapters), phone ringing, or controller logic levels

Optically isolated and clamped by transient voltage suppressor for circuit isolation and protection

Configurable through internal web pages

Power supply not required when used with a GC-100 network adapter

  • Specifications
  • Resources
Connectors

3.5mm stereo plug
Tinned leads for voltage input

Packaging

Minimum

Typical

Maximum

DC voltage input for ON

–

> 1.0V

> 1.2V

DC voltage input for OFF

< 0.8v

< 1.0V

–

AC Voltage p-p @ 5Hz to 5KHz for ON

–

> 2.4V p-p

> 2.8V p-p

AC Voltage p-p @ 5Hz to 5KHz for OFF

< 2.0V p-p

< 2.4V p-p

–

Input current

1.0mA

–

30mA

Sensor output ON @ 100μA

Vcc-0.1V

–

–

Sensor output OFF @ 100μA

–

–

0.1V

Vcc, supply voltage

4.50V

–

5.50V

Supply current

–

1.0mA

1.5mA

Documents

Quick Start
Setup and installation guide

APIs

Global Caché Unified TCP
Commands to control and configure all Global Caché products through TCP

Downloads

iHelp Setup Utility
Network discovery and setup

View Full Library
  • GC-SC1 contact closure sensor

GC-SC1 Contact Closure Sensor

The GC-SC1 detects whether isolated contacts are open or closed and monitors open-collector devices. Use it with a GC-100 network adapter or a Global Connect IR module with its port configured for sensor input.

MPN: GC-SC1

A Rapid Response To Contact Closure


Cable Length: 6 feet (1.8 meters)
Standard 2-year warranty

Ideal for determining the power state of A/V equipment

Configurable through internal web pages

Power supply not required when used with a GC-100 network adapter

  • Specifications
  • Resources
Connectors

3.5mm stereo plug
Tinned leads for contacts

Packaging

Minimum

Typical

Maximum

Sensor output from contact CLOSE

–

4.0 mS

6.0 mS

Sensor output from contact OPEN

–

75 mS

90 mS

Steady-state current for contact CLOSE

–

50μA

75 μA

In-rush current at initial CLOSE

–

1.5 mA

2.0 mA

Sensor output ON voltage @100μA

Vcc-0.1V

–

6-

Sensor output OFF voltage @100μA

–

–

0.1V

Vcc, Supply voltage

4.50V

–

5.50V

Supply current

–

50μA

100μA

Documents

Quick Start
Setup and installation guide

APIs

Global Caché Unified TCP
Commands to control and configure all Global Caché products through TCP

Downloads

iHelp Setup Utility
Network discovery and setup

View Full Library

PO Box 1659
Jacksonville, OR 97530
Tel: +1 541-899-4800
[email protected]

NEWSLETTER

Keep up with Global Caché’s latest news and events.

  • X
  • Facebook
  • Instagram
  • YouTube

Privacy Policy

All Distributors

US Distributors

International Distributors

Contact Us

MAP Pricing

Support

Downloads

Become a Partner

© 2026 Global Caché, Inc. – All Rights Reserved

Manage Consent
To provide the best experiences, we use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us to process data such as browsing behavior or unique IDs on this site. Not consenting or withdrawing consent, may adversely affect certain features and functions.
Functional Always active
The technical storage or access is strictly necessary for the legitimate purpose of enabling the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network.
Preferences
The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.
Statistics
The technical storage or access that is used exclusively for statistical purposes. The technical storage or access that is used exclusively for anonymous statistical purposes. Without a subpoena, voluntary compliance on the part of your Internet Service Provider, or additional records from a third party, information stored or retrieved for this purpose alone cannot usually be used to identify you.
Marketing
The technical storage or access is required to create user profiles to send advertising, or to track the user on a website or across several websites for similar marketing purposes.
  • Manage options
  • Manage services
  • Manage {vendor_count} vendors
  • Read more about these purposes
View preferences
  • {title}
  • {title}
  • {title}
  • Products
    • Global Connect
    • Create Custom Global Connects
    • Flex
    • iTach
    • GC-100 Network Connector
    • Solutions
  • Partners
    • All Distributors
    • US Distributors
    • International Distributors
    • Dealer Direct Program
  • News & Events
    • News
    • Events
  • Support
    • Portal
    • Get Support
    • Docs & Downloads
    • Training (YouTube)
  • Company
    • The Team
    • Marketing Resources
    • Contact Us
Control Tower
Search