﻿****Release Notes****
****iLearn IR Learner Utility****

**********************************************
Release Date: Jan. 21, 2016
Version no: 2.9
**********************************************

***Changes from iLearn Version 2.8***
* Added "Send IR Response" field to the interface next to the "Send IR" button. Response field will reflect ASCII response API codes returned from the connected learning device.
* Added "?" button next to Response field to provide verbose text of returned TCP or HTTP response.
* Added support for GC-IRL on GC-100-12/18 serial port 2.
* Added "Help" button that will open a browser window to the Global Caché iLearn Help page located at http://www.globalcache.com/support/help-ilearn/
* Added additional text to pop-up window if the "Save" button is pressed before a code is present in "Edit View."
* Changed text of IR Learner option from "iTach Flex Learner" to "Flex Learner" to avoid confusion between iTach and Flex units.


***Changes from iLearn Version 2.7***
* Added "Flex JSON (HTTP)" as a format available for the Edit View.
* HTTP option added for sending HTTP instead of TCP (for sending JSON format).  Only enabled when connected to an iTach Flex.
* Bug causing the IR Learner to fail to reconnect after sending a code has been fixed.
* Send button is disabled after sending an IR code until the send is completed.

***Changes from iLearn Version 2.6***
* Fixed bugs and reliability issues with learning and interpreting IR codes.
* The learned code is no longer editable. It can be converted to another format when clicking "Edit", where it can be edited and saved in the Edit View.
* Saved file contents are no longer shown.
* Changing the destination file no longer overwrites the contents of an existing file. "Clear" button has also been removed.  Users wishing to clear the file may modify it directly.
* Bug fixed in formatting of received codes that was causing the loss of meaningful data (often the whole code).
* Gap (new line) recognition in learned codes has been corrected.
* Standardized learned TCP connection interfaces.
* Bug fixed preventing sending IR codes to a GC-100.
* .Net version upgraded from 2.0 to 4.0
* Code format conversions updated and standardized

****Changes from iLearn Version 2.4****

* Fixed how iLearn handles exceptions.
* Implemented logic that adjusts the highlighted lines of data to automatically highlight all data until a repeat is detected.
* Several minor user interface fixes for failed connections and IR code saving.

****Changes from iLearn Version 2.3****

* iLearn now recognizes when a unit is in a state when learning is not available (LED Lighting, for example).
* iLearn now contains logic to adjust the Gap pulses value based on the frequency of the captured command.

*********************************************
***Global Caché Contact Information***
Support: support@globalcache.com
Website: http://www.globalcache.com
Support Portal: http://www.globalcache.com/support
Phone: 541-899-4800